| Research on the Application of the Automobile Drying Room Temperature Control System based on Fuzzy PID |
| XU Dongdong1, Dong Wenqi2, Yin Yuxing3, CAO Yubo1*
|
| 1. School of Information and Control Engineering,Jilin University of Chemical Technology,Jilin City 132022,China;2. CEC Compound Semiconductor Co.,Ltd., Ningbo 315336,China; 3. MMI Planning & Engineering Institute IX Co., Ltd.,Changchun city,130000,China |
|
|
|
|
Abstract The temperature control of the drying room had been an important link in the coating process and had had a significant impact on the quality of automobile coatings. In this paper, aiming at the temperature characteristics and control difficulties of the automobile coating drying room, the control algorithm of fuzzy PID had been written in the PLC, and the temperature model of the drying room had been built in Simulink. Data exchange between the PLC and Simulink had been achieved through OPC communication, and the temperature response curve had been generated to conduct simulation verification on the temperature control system of the drying room. The Simulation results show that the fuzzy PID controller is superior to the traditional PID controller in terms of stability and adjustment time, and has certain application value in solving complex temperature control problems of the drying room.
|
|
Published: 11 July 2026
|
|
|
|
|
|
|
|